Online Simulation

And More

Top Tags

  1. OMIC analysis
  2. colorectal cancer
  3. biomarker discovery
  4. health services research
  5. screening
  6. mass spectrometry
  7. proteomics
  8. proteome discovery pipeline
  9. statistical models
  10. population-based models
  11. sample acquisition
  12. metabolomics
  13. visual analytics
  14. global proteomics
  15. lipidomics
  16. cceHUB
  17. peptide synthesis
  18. cancer care engineering
  19. diet
  20. peptides
  21. XCT PLUS
  22. tool:workspace
  23. alignment
  24. multi-agent based modeling
  25. cancer care systems

Other

Support

Trouble Report

For immediate assistance browse through our support center. You can find answers to many questions in just a few minutes.

If still experiencing problems, send us a report.

required
Why the math question?

Peak Alignment of LC-MS Data

Posted 15 Sep, 2008 in Tools

Launch Tool

Available Versions

Supporting Documents

This tool is closed source.

Version 1.2 - published on 05 Jul. 2009
Contributor(s) Ann Christine Catlin
Rosen Center for Advanced Computing

George Howlett
Purdue University
At a glance Peak alignment addresses retention time shift by recongnizing and aligning significant peaks; it then uses discrete deconvolution to align overlapped peaks.
Screenshots
  • Screenshot #1
  • Screenshot #2
  • Screenshot #3
  • Screenshot #4
Description

/site/resources/2009/05/00262/alignpic1.gif In an ideal experiment, the same peptide or metabolite detected using the same analysis workflow should produce the same signal. For example, a peptide measured on the LC-MS system should have the same retention time and molecular weight for different samples. However, experimental variations may result in differences in the measured values. Peak alignment processing recognizes peaks from the same molecule occurring in different samples from the millions of peaks detected during the course of an experiment.

The xAlign software implemented in the Proteome Discovery Pipeline uses a two-step alignment approach. The first step addresses systematic retention time shift by recognizing and aligning significant peaks. A significant peak refers to a peak that is present in every sample and is the most intense peak in a certain m/z and retention time range. The second step uses discrete deconvolution to align overlapped peaks. The peak alignment tool generates the following datasets:

  • Alignment table listing the isotope label, charge state, m/z, retention time and peak intensities for each sample, as well as the number of samples in which the peak is identified and the mean intensity for each peak. This dataset serves as the input for the next step in the pipeline, the normalization,
  • Mass charge (m/z) and retention time variation,
  • Quality assessments of the data prior to moving on to the statistical testing. The assessment is based on the D value of the K-S test, the number of peaks identified in each sample and the number of peaks aligned in each sample.
credits

The xAlign algorithm and software were developed by Xiang Zhang, Jiri Adamec, et al. in 2005.

The Purdue Discovery Pipeline was created by the Bindley Biosciences Center under the direction of Charles Buck.

The integration of Purdue Discovery Pipeline models as cceHUB tools and the contribution of test datasets to the cceHUB respository are part of a collaborative effort with Jiri Adamec, Amber Jannasch and Paige Riley of the Bindley Biosciences Center and George Howlett of the Rosen Center for Advanced Computing.
references Zhang X., Assara J.M., Adamec J., Ouzzani M, Elmagarmid A.K.: Data Preprocessing in liquid chromatography-mass spectrometry-based proteomics. Bioinformatics 2005, 21(21):4054-4059.
Cite this work

If you reference this work in a publication, please cite as follows:

  • Ann Christine Catlin; George Howlett (2008), "Peak Alignment of LC-MS Data," http://ccehub.org/resources/xalign.

    BibTex | EndNote

Tags
  1. peak alignment
  2. proteome discovery pipeline
  3. proteomics